E&TC / ECE · Healthcare electronics · Final year project
Wireless Patient Health Monitoring
A wireless patient temperature monitor. A digital sensor reads the patient's temperature, the microcontroller shows it on an LCD and sends it by RF to the doctor's receiver.
What is the Wireless Patient Health Monitoring project?
A wireless patient temperature monitor. A digital sensor reads the patient's temperature, the microcontroller shows it on an LCD and sends it by RF to the doctor's receiver.
Key facts
- Branch
- Electronics & Telecommunication (E&TC / ECE); also suits Instrumentation, Biomedical
- Type
- Final year project · Intermediate
- Suitable for
- Diploma capstone and B.E / B.Tech final year
- Build time
- 4 to 6 weeks
- Estimated component cost
- ₹2,400 – ₹3,600
- Guidance from
- ₹9,999 (Hardware / IoT Final Year)
How the Wireless Patient Health Monitoring works
- 12 V power adapter / step-down transformer supplies the circuit; a regulator gives the controller and sensors a steady 5 V.
- The Pulse oximeter sensor measures heart rate and blood oxygen (SpO2) from the fingertip.
- The Push buttons and switches provide manual inputs and the power switch.
- The ATmega328P microcontroller with base board is the brain of the circuit: it samples the sensors, compares readings with set limits and switches the outputs.
- The 433 MHz RF transmitter-receiver pair sends the remote's button press wirelessly to the receiver circuit.
- The Buzzer gives an audible alert.
- The LEDs indicate status.
Block diagram
Inputs
Pulse oximeter sensorPush buttons and switchesController
ATmega328P microcontroller with base boardCommunication
433 MHz RF transmitter-receiver pairOutputs
BuzzerLEDsComponents list and cost
Typical prices from Indian online stores and electronics markets (Lamington Road, Budhwar Peth, SP Road). Buy from one store where you can to save on shipping.
| Component | Qty | What it does | Approx. cost |
|---|---|---|---|
| ATmega328P microcontroller with base board | 1 | Is the brain of the circuit: it samples the sensors, compares readings with set limits and switches the outputs. | ₹350 |
| Pulse oximeter sensor (MAX30102) | 1 | Measures heart rate and blood oxygen (SpO2) from the fingertip. | ₹300 |
| Push buttons and switches | 2 | Provide manual inputs and the power switch. | ₹80 |
| 433 MHz RF transmitter-receiver pair | 1 | Sends the remote's button press wirelessly to the receiver circuit. | ₹150 |
| Buzzer | 1 | Gives an audible alert. | ₹20 |
| LEDs (assorted) | 1 | Indicate status. | ₹20 |
| 12 V power adapter / step-down transformer | 1 | Supplies stable low-voltage power from the mains. | ₹250 |
| Passive components, PCB and wiring kit | 1 | Resistors (assorted), capacitors (assorted), transistors / MOSFETs, cables, connectors and jumper wires, diodes, PCB / breadboard and ICs and IC sockets. | ₹430 |
| Wiring, PCB, soldering and enclosure | 1 | Project overhead | ₹450 |
| Demo model base / mounting board | 1 | Project overhead | ₹500 |
| Testing spares and replacements | 1 | Project overhead | ₹300 |
| Estimated total | Varies with brand, quality and city | ₹2,400 – ₹3,600 |
Prices are estimates for budgeting. We confirm the bill of materials when your design is frozen, and components are charged at actual cost with bills.
How much does this project cost?
| Option | What you get | Cost |
|---|---|---|
| Components only | You buy the parts and build it yourself | ₹2,400 – ₹3,600 |
| Hardware / IoT Final Year | Working model or guided build, Circuit diagram and bill of materials, Firmware / code with explanation | from ₹9,999 + components |
| Capstone Project (CPE) | Working project or model, Black book in MSBTE format, Step-by-step explanation | ₹9,999 + components |
| Diploma ITR | 100% working source code, Project report PDF, PPT | ₹1,999 + components |
No GST and no hidden charges. Use the cost calculator for a quote with your deadline and add-ons, or see all plans.
Download the project brief (PDF)
Summary, working, components and cost and viva questions on one branded PDF to show your guide or team. To get it developed, contact us on WhatsApp.
What you submit with this project
- Working model with circuit diagram and program code
- Project report or black book in your university's chapter order (block diagram, circuit, calculations, results)
- Presentation for the review and final viva
- Synopsis for topic approval, if your college asks for one
E&TC / ECE viva questions on this project
What is the aim of the Wireless Patient Health Monitoring project?
A wireless patient temperature monitor. A digital sensor reads the patient's temperature, the microcontroller shows it on an LCD and sends it by RF to the doctor's receiver.
Explain the working of your project in short.
12 V power adapter / step-down transformer supplies the circuit; a regulator gives the controller and sensors a steady 5 V. The Pulse oximeter sensor measures heart rate and blood oxygen (SpO2) from the fingertip. The Push buttons and switches provide manual inputs and the power switch. The ATmega328P microcontroller with base board is the brain of the circuit: it samples the sensors, compares readings with set limits and switches the outputs.
Why is a microcontroller used in this project?
A microcontroller combines a CPU, memory and I/O pins on one chip, so a single low-cost IC can read sensors, make decisions in code and control loads without a computer.
How is the heart rate measured optically?
Red and infrared LEDs shine into the finger and a photodetector measures the light absorbed by blood. Each heartbeat changes the blood volume, so the reflected light pulses at the heart rate.
Why is a pull-up resistor needed with a push button?
Without it the input pin floats and reads random values. The pull-up keeps it HIGH until the button connects it to ground.
Why are encoder and decoder ICs used with the RF module?
The HT12E encoder converts parallel button inputs into a serial code with an address, and the HT12D decoder on the receiver checks the address and restores the outputs. This prevents interference from other remotes.
What is the difference between an active and a passive buzzer?
An active buzzer has a built-in oscillator and beeps on DC. A passive buzzer needs a square wave from the controller, which allows different tones.
Explain the block diagram of your project.
The input section senses the real-world quantity, the ATmega328P microcontroller with base board processes it according to the program, and the output section acts locally and sends the data or alert wirelessly. The power supply section feeds every block.
Which communication protocols are used between the modules?
Analog inputs read by the ADC for the analog sensors. Each protocol was chosen because the module supports it and it uses the fewest pins.
What is the operating voltage of the circuit?
The controller and most sensors work at 5 V (ESP boards and some modules at 3.3 V). A 12 V adapter powers the board, and a regulator steps it down. Motors and relays get their own supply line so they do not reset the controller.
What is the difference between accuracy and precision?
Accuracy is how close a reading is to the true value. Precision is how close repeated readings are to each other. A sensor can be precise but inaccurate if it is not calibrated.
How do you ensure patient safety?
The device runs on low-voltage batteries, has no direct mains connection to the patient, uses isolated sensors and limits current through any electrode. Alarms are set for abnormal readings.
Related projects
Academic use: Project Buddyy offers mentoring, guidance and reference material for learning. You stay responsible for following your institution's academic integrity rules and for understanding everything you submit.
Want to build Wireless Patient Health Monitoring?